ONKYO TX-NR1030 - AV Receiver - Service mode - Function checks - Idle current adjustments - Firmware update procedure - AV receiver Repair and service - Manual Tips
Category: AV Receiver Repair and Service
Contents of this article
- Service mode access
- Idle current setting
- Firmware Update
ONKYO TX-NR1030
SERVICE INFORMATION MODE
Displaying Service information
This service information display system is helpful in analyze the status when the unit goes into Protect mode and is powered off
Pay attention that the status will change if a button is pushed.
1. Press twice the ON/STANDBY key while pressing the DISPLAY key.
The version of main microprocessor is displayed only for 3 seconds.
2. Press HOME button within 3 seconds above.
3. Press HOME button again. The following information are dispiayed.
01:23 10h + Information Dispiayed (Record this information)
4. Press ONISTANDBY button to exit the display of service information.
(Ref; Press RETURN button to initialize the data in the service information.)
NOTATION ABOUT ENTERING TEST MODE BY PRESSING BUTTON
In this procedure, the following notations are used to simplify explanation of how to press button.
e.g.-1 [TWCD] + [ONISTANDBY] --> [BDIDVD]
This means "While holding down TWCD button, press ONISTANDBY button then release both buttons and then press
BDIDVD button".
e.g.-2 [DISPLAY] + [ONISTANDBY] *2 _> [DIMMER]
This means "While holding down DISPLAY button, press ONKSTANDBY button twice then release both buttons and then press
DIMMER button".
INITIAL SETTING FOR SHIPPING
Initialization of memories.
Do the following operation.
[CBLISAT] + [ONISTANDBY]
Unplug the power cord from AVR after the FL tube displays "Clear" and AVR goes standby.
CONFIRMATION OF MAIN CHECKSUM
MAIN Checksum can be confirmed the following operation.
[DISPLAY] + [ON/STANDBY] * 2 Q [MEMORY]
CONFIRMATION OF OUTPUT VOLTAGE AND THERMAL SENSOR
Temperature and output voltage can be confirmed the following operation.
[DISPLAY] + [ONISTANDBY] * 2 > [MEMORY
CONFIRMATION OF MODEL NAME AND DESTINATION
Model name and destination can be confirmed the following operation
[TVICD] + [ONISTANDBY] -> [DlMMER](RT!PTY!TP) -> [TONE+] *4
TEST MODE FOR OPERATION
Do the following operation.
1. Set the following VOL level.
VOL level : 30
2. [TWCD] + [ONISTANDBY]
CONFIRMATION OF VOLTAGE-DETECTION PROTECTORS.(The following model only)
Applied model TX-NR1 0301/3030, DTR-60.61"./0.6
<NOTE>
Don't connect load nor short speaker terminals.
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TWCD] + [ONISTANDBY] --> [BDIDVD]
1-3. [TONE +]
to the following test mode.
TES T 1-01
2. AVR automatically tests in the following test sequence. And if it is all OK, Wi-Fi test will begin.
Test sequence
(FL+)-->(FR-)-->(C+)-->(SL-)-->(SR+)-->(SBL-)-->(SBR+)-->(FWL-)-->(FWR+)-->(FHL-)-->(FHR+)
3. If FL tube displays Wi-Fi check mode then voltage-detection protectors test will be completed.
CONFIRMATION OF UPDATE ROUTE.
1. Do the following operation.
1-1. set the volume level to 30
1-2. [FVICD] + [ONISTANDBY] --> [BDIDVD]
1-3. [TONE +]
to the following test mode.
TES T 1-01
2. Once the above mentioned test mode is entered, voltage-detection protectors function is checked automatically first, then update route check will begin.
If the result of update route check is no problem then Wi-Fi check will begin. If the result is NG then NG message will be shown on the FL tube.
3. If FL tube displays Wi-Fi check mode then voltage-detection protectors test and update route check are passed.
CONFIRMATION OF Wi-Fi CONNECTION (The following model only)
Applied model TX-NR1030/3030,PR-SC5530
1. Setting Wi-Fi routers.
2. set the following test mode.
TEST 1-O1
3. Once the above mentioned test mode is entered, voltage-detection protectors function is checked automatically first, then update route check will begin and then Wi-Fi check will begin.
In Wi-Fi check mode, it connects an access point automatically. Wi-Fi LED flashes during connection.
4. If connection is completed and IP address is successfully acquired, Wi-Fi LED turning lights off and the value of RSSI to an access point is displayed in dBm.
If the connection is failed, NG is displayed.
In case value of RSSI level isn't showed on the FL tube at all past 4 minutes in this timer mode, judge as NG.
If the connection is failed, exit the idling timer mode by pressing the TWCD button and please try again from step-1.
CONFIRMATION OF CURRENT DETECTION PROTECTORS (The following model only)
Applied model ITX-NR1030/3030, DTR-60.6f70.6
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TVICD] + [ONISTANDBY] -> [CBL.lSA‘l]
1-3. [TONE -]
to the following test mode.
TEST 1-0.9
2. Confirm that relay is not cut off even if you connect the following load A to the following channels one by one.
3. Confirm that relay is cut if you connect the following load B to the following channels one by one.
Channel FL, FR, C, SL, SR, SBL, SBR, LH, RH, LW ,RW ch LW ,RW ch : TX-NR3030, DTR-70.6 only
Load A 3 ohm
Load B 1 ohm
CONFIRMATION OF OUTPUT SENSOR
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TVICD] + [ONISTANDBY] --> [CBL.lSA‘l]
1-3. [TONE - ] *2 and (*3)
to the following test mode.
TEST 1-07 and TEST 1-08
After lighting "FM STEREO" on the FL tube.
Relays RL6901, RL6902, RL6903, RL6904
CONFIRMATION OF COOLING FAN OPERATION
Applied model ITX-NR1030f3030, DTR-60.6f70.6
1. Confirm fan that is not rotating.
2. Set the following test mode and confirm fan that is rotating at HIGH speed.
TEST 1-07
3. Set the following test mode B and confirm fan that is rotating at LOW speed.
TEST 1-08
CONFIRMATION OF KEY OPERATION
1. Do the following operation.
1-1. set the volume level to 30
1-2. [TWCD] + [ONTSTANDBY] --> [CBLISAT]
1-3. [TONE - ] *4
to the following test mode.
TEST 1-06
2. Confirm each key and master volume operation.
3. If "ON,*'STANDBY" button is pressed, AVR escapes from this KEY test mode.
Therefor, press the "ONISTANDBY" button, after checking other buttons finished.
CONFIRMATION OF FL TUBE AND LED
1. Do the following operation.
[TVICD] + [ONISTANDBY] -> [DIMMER]
2. Confirm that all LEDs and all segments of FL tube are lit.
CONFIRMATION OF HEAD PHONE OPERATION
Confirm the headphone mark when headphones plug is inserted into the PHONES jack.
CONFIRMATION OF FM RADIO OPERATION
1. Setting of Signal Generator(SG)
Carrier frequency any
Modulation 1kHz
Deviation 75kHz
Output level 35dBu
2. Waveform confirmation
Set the signal of SG as following channels and confirm output is the following.
Output
Lch R ch
(1) R ch only No Yes
(2) L + R ch Yes Yes
3. Confirmation of Stereo indicator
Set SG as stereo and confirm stereo indicator is on.
SG Input
4. Confirmation of Auto stop operation
Do auto tuning (Press TUNING UP or TUNING DOWN button) and confirm that the searching stops when a station that is set by SG is found.
CONFIRMATION OF RDS (RADIO DATA SYSTEM) OPERATION (Applied to MPPIMPBIMM* type)
1 Input 98MHz,30dBp signal modulated with RDS data.
DS TEST" shall be displayed within 2 seconds
2. When a PS information is received, the name of the station "R
instead of the frequency.
CONFIRMATION OF OSD(ON SCREEN DISPLAY) OPERATION
1. When HOME button is pushed confirm that setup menu is displayed in HDMI Out.
2. Confirm that specified operations for ENTER(with 4-cursor) buttons are made.
CONFIRMATION OF CEC OPERATION
1. Connect AVR's HDMI OUT to HDMI input of appliance compatible with CEC(SlNK or REPEATER] by HDMI cable.
2. Turn on the power to the AVR
3. Do the following operation.
3-1. set the volume level to 30
3-2. [TVICD] + [ONISTANDBY] --> [AUX]
to the following test mode.
TEST 6-00
FL tube will display "OK" or "NG".
CONFIRMATION OF DOLBY TEST TONE
1. Press TEST TONE on remote controller then press CH SELECT repeatedly.
Set turn to Dolby Test mode tone Check speaker condition.
2. Please check that a sound comes out from each channel.
--> FL ch -> C ch --> FR ch --> SR ch --> SBR ch --> SBL ch --> SL ch -> SW ch -->
CONFIRMATION OF FL DISPLAY
1. D0 the following operation.
1-1. set the volume level to 30
1-2. [TVICD] + [ONISTANDBY] ---> [DIMMER(RT/PTY/TP)]
to the F1. test mode
TONE+ = Step up
TONE- = Step down
The contents of the step are as follows.
1. Lit all segment and LED
2. Lit '23456789ABCDEF' and LED.
3. Lit a even number segment and LED.
4. Lit an odd number segment and LED.
5. The Destination setting is displayed and LED.
ADJUSTMENT OF IDLING CURRENT
Applied to the following model.
(Model TX-NR1030/3030, DTR-60.6/70.6
Procedure
a. Pre-adjustment
Set the following registers to minimum position before POWER ON.
Set the voltages at the following terminals to the following voltage by adjusting the following registers, under the condition of no input and no load, immediately after POWER ON.
TX-NRSOSO, DTR-70.6
Channel L/C/R/ SL/SR/SBL/SBR/LH/RH/LW/RW
Check point(Terminals) P6070 -6080
Adjustment point (Registers) R6040>6049,R6360
Voltage 3.0mV
TX-NR1030, DTR-60.6
SL/SR/SBL/SBR/LH/RH
Check point(Terminals) P6070-P6078
Adjustment point (Registers) P6040----P6048
Voltage 3.0mV
Common adjustment for both models
b. Aging
Heat run during the following time.
Time 4>6 minutes
c. Final adjustment
Re-adjust by the following procedure after heat running for the above mentioned time.
L/C/R/SL/SR/SBL/SBR/LH/RH/LW/RW
Below 4mV to 4mV
Between 4~6mV Do not adjust.
Over 6mV to 6mV
FIRMWARE UPDATE
USB Update (service mode)
Preparation
1. Connect the USB storage device to your PC. If there is any data in the USB storage device, remove it.
2. Download the firmware file
3. Copy it to the USB storage device. Be careful not to copy the zip file
Overwriting is also possible.
1. Tum on the unit. It takes some time to start after you switch on the unit.
2. Select the USB input source.
3. Connect the USB storage device to USB port on the unit. Wait until Initializing of USB/N ET finishes
4. Hold down [DISPLAY] button and then press [ON/STANDBY] button twice.
Main version will be displayed, and HYBRID STANDBY indicator will start to flash.
5. Press [RETURN] button. “NET -> ALL_D" will be displayed.
6. Select “USB -> ALL_D" by [PRESET(left/right)] cursors and [TUNlNG(up/down)] cursors,
then press [ENTER] button, updating will begin.
7. Wait until update is completed. “Then the update ends, “Completed!” is displayed.
(If you leave it, it automatically turns standby mode. )
8. Press [ON/STANDBY] button, and the unit turns on.
9. Check the new FW version number.
ONKYO TX-NR1030 - AV Receiver - Service mode - Function checks - Idle current adjustments - Firmware update procedure - AV receiver Repair and service - Manual Tips