Ads Below The Title

SHARP LC-32D653E - LC-32D654E - Software update - white balance adjustment - Factory rest – LCD television Repair and service - Manual Service

Category: LCD Television Repair and Service 

Contents of this article 

  • Software update procedure 
  • White balance adjustment 
  • Factory Reset 

SHARP LC-32D653E - LC-32D654E

ADJUSTMENT PROCEDURE
1. Adjustment method after PWB and/or IC replacement due to repair
The unit is set to the optimum at the time of shipment from the factory. If any value should become improper or any adjustment is necessary due to
the part replacement, make an adjustment according to the following procedure.
1. Procure the following units in order to replace the main unit, IC8101.
NOTE: [Caution when replacing ICs in the main unit (IC1504)]
The above ICs are EEPROMs storing the EDID data of HDMI. Before replacing the relevant part, procure the following parts in which the data
have been rewritten.
MAIN UNIT: DUNTKE685FM31 (LC-32D653E)
DUNTKE685FM33 (LC-32D654E)
IC1504 RH-iXC442WJN1S EDID (HDMI)
IC1503 RH-iXC697WJQZS EDID (PC)
Upgrading of each microprocessor software
Caution: Never “POWER OFF” the unit when software upgrade is ongoing.
Otherwise the system may be damaged beyond recovery.
Software version upgrade
The model employs the following software.
# Main software
# Monitor microprocessor software
The main software and the monitor microprocessor software can be upgraded by using a general-purpose SD memory card.
The followings are the procedures for upgrading, explained separately for each of the main software, the monitor microprocessor software.
Main software version upgrade
Get ready before you start
# SD memory card of 32MB or higher capacity
# PC running on Windows 98/98SE/ME/2000/XP operating system
# SD memory card reader/writer with USB connectivity.
# SD memory card formatting software (Downloadable at //panasonic.jp/support/)
Preparations
To upgrade the main software, it is necessary to get ready the SD card for version upgrade before you start.
Follow the steps below and create the SD card for version upgrade.
1. Insert the SD card into the SD card reader/writer. Start the SD card formatting software. Click [Format].
(When you have the drive options, select the drive where the SD card is inserted before you proceed.)
2. When the formatting is over, Click [OK].
3. Click [Exit] to finish the formatting.
NOTE: When you are done, take out the SD card once to make sure it is finished, and then insert it again.
4. Copy the binary image file D42UAxxx.SDC (named temporarily) for version upgrade to the root directory (folder) of the SD card drive.
NOTE: In the SD card drive, do not store other folders or unrelated files, or more than one binary image files for version upgrade.
Now the SD card for version upgrade is ready.
How to upgrade the software
5. Shut off the AC power (i.e. unplug the AC cord).
6. Insert the SD card for version upgrade (prepared as above) into the service socket located lower side from center at terminals, under DIGITAL
AUDIO OUTPUT terminal in the rear of the unit, in a way that the cut corner of the SD card comes at the upper side.
NOTE: If the SD card is inserted in a wrong way, the card will go deep inside the unit beyond retrieval. Take due care to insert the SD card correctly.
7. Turn on the AC power (i.e. plug in the AC cord).
8. After the unit startup, the system upgrade screen will appears within 15~30 seconds.
9. Even a single failure in the process will trigger the upgrade failure screen as shown below. The word “NG” changes to red for the item failed.
NOTE: In the event of a failure, repeat the upgrading process. If the process repeatedly fails, it is likely that the hardware is troubled.
10.Upon completion of the whole process, the upgrade success screen appears. You can check the new software version on this
screen. The version information appears after the upgrade is complete.
11.Shut off the AC power to the unit (unplug the AC cord), and remove the SD card for version upgrade.
12.Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the main
software version information
Monitor microprocessor software version upgrade
NOTE: If “Monitor version” in the process menu is “2.00M”, the monitor microprocessor software can not be rewritten (because IC2002 has been
replaced with the mask type).
Get ready before you begin
Get ready the same items as listed in the “Main software version upgrade”.
Preparation
Create the SD card for monitor microprocessor software version upgrade in the same manner as explained in the “Main software version upgrade”. Copy the binary image files D42UMxxx.SDC and D42UMxxx.BIN (named temporarily) for monitor microprocessor software version upgrade to the SD card drive.
How to upgrade the software
1. Shut off the AC power to the unit (i.e. unplug the AC cord).
2. Insert the SD card for version upgrade (prepared as above) into the service socket located lower side from center at terminals, above S-VIDEO terminal in the rear of the unit, in a way that the cut corner of the SD card comes at the upper side.
NOTE: If the SD card is inserted in a wrong way, the card will go deep inside the unit beyond retrieval. Take due care to insert the SD card correctly.
3. Turn on the AC power (i.e. plug in the AC cord).
CAUTION: The moment this operation is done, the upgrading of the monitor microprocessor software starts. While the upgrade is ongoing, never power off the unit. Otherwise the upgrade will fail and the system may have a serious damage beyond recovery (inability to start).
4. After the unit startup, the system upgrade screen  appears within 15~30 seconds.
5. A failure in the process will trigger the upgrade failure screen. The word “NG” changes to red for the item failed.
NOTE: In the event of a failure, repeat the upgrading process. If the process repeatedly fails, it is likely that the hardware is troubled.
6. Upon completion of the whole process, the upgrade success screen as shown below appears. You can check the new software version on this screen. The version information appears after the upgrade is complete.
7. Shut off the AC power to the unit (unplug the AC cord), and remove the SD card for version upgrade.
8. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the monitor microprocessor software version information.
White balance adjustment
[Adjustment procedure]
1) Using the remote controller, transmit the “monitor adjustment process” code.
2) Set the 6th point to the specified gradation level. With the strongest color being fixed, turn down the R, G and B settings to their reference levels.
3) Set the 5th point to the specified gradation level. Correct the G setting (800 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
4) Set the 4th point to the specified gradation level. Correct the G setting (680 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
5) Set the 3rd point to the specified gradation level. Correct the G setting (480 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
6) Set the 2nd point to the specified gradation level. Correct the G setting (232 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
7) Set the 1st point to the specified gradation level. Correct the G setting (184 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
8) With the MSET0003 command, write the adjustment values and turn off the AC power.
# Initial R, G and B settings at point 6: Gradation level set at 928
# Initial R, G and B settings at points 1 thru 5: Corrected G setting at each point (This is because the adjustment is made to achieve the same remainder of RGB setting /
4 at each point.)
[Adjustment value]
#As per the “standard set” submitted by Engineering Department
“LC-32D42U” Teaching set
[Adjustment reference] Instrument: Minolta CA-210 Engineering instrument

Level
Reference
Adj. spec
Ins. spec
Point 6

928

X=0.272
±0.0010

±0.0020

y=0.277
Point 5

800

X=0.272
±0.0010

±0.0020

y=0.277
Point 4

680

X=0.272
±0.0010

±0.0020

y=0.277
Point 3

480

X=0.272
±0.0010

±0.0020

y=0.277
Point 2

232

X=0.272
±0.0020

±0.0030

y=0.277
Point 1
184
X=0.272
±0.0020
±0.0030
y=0.277

Factory settings
# Move the cursor to the [INDUSTRY INIT (+Cause)] line. Using the [VOL+/-] keys, set this item ON and press the [ENT] key.
The version confirm window appears on the green
screen. When [SUCCESS] appears at the top, the factory settings are complete. (If an error occurs. [ERROR] appears on the red screen.)

# Finally turn off the AC power.
The following settings are returned to the factory ones.
1) User settings
2) Channel data (broadcast frequencies, etc.)
3) Password setting
4) Operation time
5) Automatic installation flag
6) V-CHIP block setting
SHARP LC-32D653E - LC-32D654E - Software update - white balance adjustment - Factory rest – LCD television Repair and service - Manual Service SHARP LC-32D653E - LC-32D654E - Software update - white balance adjustment - Factory rest – LCD television Repair and service - Manual Service Reviewed by Womens special on February 14, 2016 Rating: 5

No comments

Ads Inter Below The Post
Image Link [https://lh3.googleusercontent.com/-wlvSkBWGUW0/AAAAAAAAAAI/AAAAAAAAAxU/6FpWSjn-h2o/s120-c/photo.jpg] Author Name [Sora Templates] Author Description [Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry's standard] Facebook Username [#] Twitter Username [#] GPlus Username [#] Pinterest Username [#] Instagram Username [#]